Universal expansion module

High flexibility in organizing the input/output subsystem (I/O)

Universal FMR I/O modules are designed to increase the number of channels in automated control and data acquisition systems. The modules combine with controllers of any manufacturer through the Modbus-RTU protocol with connection to the RS-485 port.

There are 11 modifications of modules that allow you to choose the optimal for your task combination of discrete and analog I/O. Cascading FMR modules to each other greatly increases the overall capacity of the I/O system. In total, up to 341 FMR modules can be assembled into a network, providing up to 10912 channels. *

User manual
Download liner file
Download FMR Configurator
Connection to the controller of any manufacturer through the RS-485 port
Up to 16 analog inputs
in one module
In setup mode,
USB powered

Features

Scalability

The FMR module contains two RS-485 communication ports. Such organization of ports makes it possible to build systems with a large number of inputs/outputs and the ability to interrogate the system with any external Master device.

Supports
up to 341 modules

Over
10 000 I/O

Up to 341 FMR modules can be connected to one Master device, providing over 10,000 I/O channels!

The addressing of new channels is absolutely transparent to the control system, does not require additional computing resources. It is carried out by the base FMR module.

Reliability

The module is equipped with a protected power supply with a wide input range of supply voltages, inputs, outputs and communication ports resistant to overload. In the event of emergencies leading to loss of communication between the module and the control controller or modules connected to each other, in order to maintain control over the state of the object, FMR is able to switch to safe operation mode.
Shielded connections provide added protection for network data.

Convenience and simplicity

The front panel of the module is equipped with LEDs informing the user about the operation mode of the inputs / outputs and the status of the module.

The COM1 network address is conveniently set using the five-position DIP switch located under the system compartment cover.
All the settings necessary for the operation of the FMR modules are collected in the FMR-Configurator utility.


A paper marking insert on the front panel of the device is useful for connectors marking.

Download the liner file

* Module FMR - 2222-10-0 modification

Operation

The module is configured via the USB port. For configuration the FMR Configurator utility for PC is available for download from our website.

Alignment

By using the configurator you can configure the network connection settings.

For analog inputs you can select the types of analog sensors that will be connected to them. In addition, if necessary, any analog input can be switched to discrete mode of operation.

For each output (DO, AO), the safety status parameters are configured.

All conversions can be performed both for each channel individually or for a dedicated channel group.

Debugging

An important function of the configurator, in addition to setting, is debug mode. The configuration program allows you to debug the operation of the system, module and all devices connected to it via the system bus. This mode is indispensable when you need to check the operation of sensors, actuators at the facility. At the end of debugging, the system configuration can be saved to a file.

Software update of the FMR module is also performed using the configurator.

Characteristics

Discrete inputs
Discrete outputs
Amount
 
 

Nominal voltage

Galvanic isolation

up to 32,
inverting input function support

24V AC/DC

Group, 8 inputs per group

Optical relay
(opto)

Triac
(triac)

Relay
(relay)

until 12
Protection Type: Combined

until 8
Protection Type: Combined

until 12
Protection Type: None

Analog inputs
Analog outputs
Amount

Supported types of temperature sensors (programmable)

Operating modes (set by software)
 
 
 
 
 

Type of protection

Up to 16 universal

RTD,
NTC,
User configurable

Temperature Measurement: Resolution 0.1ºC,
0-10V signal measurement: 3mV resolution,
4-20mA signal measurement: 6μA resolution
Discrete input mode

Combined up to 36V

Amount

Current-carrying rating (load)

Type of protection
 
 

up to 4 outputs 0-10V

5mA
 

Combined up to 36V

Power
Interfaces
Nominal voltage

Performance range
 

Voltage rating

Power consumption

USB powered
 

24V AC/DC

16…48VDC
18…36VAC

60V

up to 5.4W

To configure and update software

RS-485
(COM1)
 

RS-485
(COM2)
 

Ext Connector
 
 

USB-device
 

Galvanically isolated,
Connector: Terminal Block,
Protocol: Modbus-RTU

Galvanically uninsulated,
Connector: Terminal Block,
Protocol: Modbus-RTU

MRL module connection
(total amount will be indicated later)

USB 2.0,
Connector: Micro-B type

Dimensions
Terms of Use
Width

Height

Depth

Weight

Fastening
 

140 mm

110 mm

55 mm

300 g

DIN rail
Type: TH35 / 7.5 / 15

Temperature
 

Humidity
 

from -20°С to + 55°С
no freezing

up to 90%
non-condensing

Modification group

It is possible to combine the USO boards and get 225 different modifications. Choose the desired modification in the Price list.
Vendor code
Din
Dout
Ain
Aout
relay
triac
opto
FMR - 1020-10-0
8
6
-
2
8
2
FMR - 1021-10-0
8
5
-
1
8
4
FMR - 1320-10-0
8
6
2
2
6
2
FMR - 1321-10-0
8
5
2
1
6
4
FMR - 3022-10-0
16
12
-
-
-
-
FMR - 3322-10-0
16
8
4
-
-
-
FMR - 3422-10-0
16
8
-
4
-
-
FMR - 3030-10-0
-
24
-
-
-
-
FMR - 2222-10-0
32
-
-
-
-
-

* - Inactive modifications are temporarily unavailable for order.